logging console

This command enables logging to the console. You can specify the severitylevel value as either an integer from 0 to 7 or symbolically through one of the following keywords: emergency (0), alert (1), critical (2), error (3), warning (4), notice (5), info (6), or debug (7).

Default Disabled; critical when enabled
Format logging console [severitylevel]
Mode Global Config

www.lancom-systems.com